GM Tech Tip: Torque-To-Yield TTY Fastener Use And Reuse -

GM Tech Tip: Torque-To-Yield TTY Fastener Use And Reuse

A fastener with a torque + angle specification must be tightened first to the torque part of the specification and then tightened further by the addition of the specified angle. The angle must be applied relative to the mating fastener.

torque-wrench-500
The desired result of tightening a fastener is to obtain a proper clamping force between parts. The clamping force prevents loosening when the vehicle is in use and external forces act on the clamped parts. All fasteners have a specified torque. The method used for a particular application is determined by engineering and specified in the service information. It is necessary to apply the fastener torque to the specific fastener identified. Applying torque to the mating fastener can damage the fastener, mating components or provide insufficient clamp load.

There are three different methods for the specification of tightening fasteners:

Torque (T)

Torque + Angle (TA)

Torque + Angle-to-Yield (TAY) (sometimes referred to Torque-to-Yield (TTY)).

Torque

A fastener with a torque specification can be tightened with a conventional torque wrench. Generally, externally threaded fasteners (bolts, screws, studs) tightened to this specification method can be reused unless otherwise specified in the service information.

Torque + Angle

A fastener with a torque + angle specification must be tightened first to the torque part of the specification and then tightened further by the addition of the specified angle. The angle must be applied relative to the mating fastener, if present, or relative to the mating surface. A backup wrench must be used, if required, to prevent the rotation of the mating fastener while the angle is added to the fastener with the torque + angle specification. Generally, externally threaded fasteners tightened to this specification method can be reused unless otherwise specified in the service information.

Torque + Angle-to-Yield

A fastener with a torque + angle-to-yield specification is tightened in the same way as the fastener with the torque + angle specification. The difference between a torque + angle specification and a torque + angle-to-yield specification is that the tightening results in permanent deformation of the externally threaded fastener. Externally threaded fasteners tightened to this specification method must not be reused and must ALWAYS be replaced if loosened.

Tightening in Stages

Generally, service information specifies a fastener tightening specification in stages. An individual fastener with a torque specification is tightened to the specified torque in one pass.

For torque + angle and torque + angle-to-yield specification fasteners, the fasteners are tightened in stages. All the fasteners are tightened to a torque specification on the first pass. Next, they receive another tightening to a specified angle on the second pass. Sometimes more than two passes are required. Always refer to the appropriate service information for proper tightening in stages.

On applications with more than one fastener, such as wheel nuts or cylinder head bolts, the fasteners should be tightened to specification by alternating between the fasteners to ensure the parts are not distorted and that the fasteners are torqued evenly. Once a specified minimum of torque has been achieved for each bolt, the bolts should be tightened completely to specification.

Reusing the Fastener

Think of an externally threaded fastener (bolt, screw or stud) as a spring. As the threads are tightened, the spring is stretched. With a conventional torque or torque + angle tightening specification, the spring returns to its original length when loosened. In the case of a torque + angle-to-yield tightening specification, the spring is overstretched (plastically deformed) and does not return to its original length. For this reason, the torque + angle-to-yield tightening specification requires the externally threaded fastener to ALWAYS be replaced.

Courtesy of Mitchell1.

You May Also Like

Diagnostic Procedures For Stop/Start Systems

Stop/start technology is more than just a switch wired to the brake pedal and starter.

When trying to resolve a complaint, code or no-start/no-crank condition on a stop/start vehicle, it is essential to know how the system operates. The problem may not have a complicated reason – something simple may be causing the stop/start system not to work.

The greatest obstacle to the advancement of stop/start technology is the driver’s and technician’s lack of trust in and knowledge of the technology. Many older drivers and technicians fear that stopping and starting the engine will cause a shorter life for the battery, starter and engine. But the real fear is that the engine will not start again at a green light. 

Brake Pad Wear Sensors

Brake pad wear sensors have been around for years and continue to evolve.

Topology and Your Scan Tool

Topology influences how you access the modules with your scan tool.

Ride Control Diagnostics From Tire Wear Clues

Learning how to read the tire and communicate your findings is the key to ride control service.

Understanding Engine Timing- Chains, Gears and Belts

Engine timing is critical for overall performance.

Other Posts

Air Filters and Fuel Trims

Modern engines rely on precise airflow and oxygen sensor data for optimal performance.

Mercedes Ignition Coil Pack Diagnostics

Replacing a single coil might not be the best approach to curing an engine of a chronic misfire.

Understanding Fuel Injection

Though many different terms have been used for the technology, it really just comes down to indirect or direct.

Brake Line Replacement Options

We’ve got all the rules for replacing brake lines for you right here.